Features
7-inch LCD touchscreen with intuitive user interface accomplishes detection without the need to connect to a computer
Only requires 0.5 - 2µl sample volume for accurate measurement.
Full spectral range of wavelength detection from 190nm to 800nm.
Simply power it on and start measuring, no need for lamp warm-up.
The Xenon flash lamp has long service life up to 10 years.
Automatic detection on lowering the pedestal arm.
OD600 function to detect concentration of bacteria and microorganisms.
For fluorescence detection, it can be used for accurate quantification of extremely low concentration nucleic acid with a lower limit of 0.5pg/µl(dsDNA).
The test result can be printed by a built-in printer or exported via USB for data analysis and storage.
Fluorescence detection function
The advanced model (SPT-NanoF) comes with fluorescence detection module. When used with fluorescence quantitative analysis kit it accurately quantifies the concentration of DNA, RNA and protein through the specific binding of fluorophore with target material.
Applications
The Micro Volume Spectrophotometer is used in the detection of micro-volume quantities of nucleic acids, proteins, chemical substances and liquids in laboratory, food industries, chemistry, microbiology, medicine research and development.
Features
7-inch LCD touchscreen with intuitive user interface accomplishes detection without the need to connect to a computer
Only requires 0.5 - 2µl sample volume for accurate measurement.
Full spectral range of wavelength detection from 190nm to 800nm.
Simply power it on and start measuring, no need for lamp warm-up.
The Xenon flash lamp has long service life up to 10 years.
Automatic detection on lowering the pedestal arm.
OD600 function to detect concentration of bacteria and microorganisms.
For fluorescence detection, it can be used for accurate quantification of extremely low concentration nucleic acid with a lower limit of 0.5pg/µl(dsDNA).
The test result can be printed by a built-in printer or exported via USB for data analysis and storage.
Fluorescence detection function
The advanced model (SPT-NanoF) comes with fluorescence detection module. When used with fluorescence quantitative analysis kit it accurately quantifies the concentration of DNA, RNA and protein through the specific binding of fluorophore with target material.
Applications
The Micro Volume Spectrophotometer is used in the detection of micro-volume quantities of nucleic acids, proteins, chemical substances and liquids in laboratory, food industries, chemistry, microbiology, medicine research and development.
Model | SPT-NanoF (With Fluorescence Detection) | SPT-Nano |
Wavelength range | 190-800nm | |
Minimum sample size | 0.5~2μL | |
Path length | 0.05mm(high concentration) | |
Light source | Xenon flash lamp | |
Detector type | 2048px, CMOS | |
Wavelength accuracy | 1nm | |
Spectral resolution | ≤3nm | |
Absorbance precision | 0.003Abs | |
Absorbance Accuracy | 1%(7.332Abs at 260nm) | |
Absorbance Range | 0.04~300A | |
Lower Limit of Detection | 2 ng/μL(dsDNA); 0.06 mg/mL (BSA) | |
Maximum Concentration | 15,000 ng/μL(dsDNA); 440 mg/mL (BSA) | |
Sample pedestal material | Aluminum alloy and Quartz fiber | |
Power suppler | DC 12V 4A | |
Operating power | 48W | |
Standby power | 8W | |
Software | Android | |
Data Output | USB 2.0, in-built printer | |
OD600nm Measurement | ||
Light source | LED | |
Wavelength range | 600±8nm | |
Absorbance range | 0~4A | |
Fluorescence detection | ||
Type of tube | 0.5ml PCR Tube | — |
Excitation filters | wavelength 440nm (bandwidth 70nm) | — |
Emission filters | wavelength 545nm (bandwidth 30nm) | — |
Sensitivity | dsDNA: 0.5pg/μL | — |
Linear dynamic range | R2≥0.995 | — |
Repeatability | ≤1.5% | — |
Dimensions and Weight | ||
Dimension (W x D x H) | 318*220*205mm | |
Weight | 4.1kg |
Model | SPT-NanoF (With Fluorescence Detection) | SPT-Nano |
Wavelength range | 190-800nm | |
Minimum sample size | 0.5~2μL | |
Path length | 0.05mm(high concentration) | |
Light source | Xenon flash lamp | |
Detector type | 2048px, CMOS | |
Wavelength accuracy | 1nm | |
Spectral resolution | ≤3nm | |
Absorbance precision | 0.003Abs | |
Absorbance Accuracy | 1%(7.332Abs at 260nm) | |
Absorbance Range | 0.04~300A | |
Lower Limit of Detection | 2 ng/μL(dsDNA); 0.06 mg/mL (BSA) | |
Maximum Concentration | 15,000 ng/μL(dsDNA); 440 mg/mL (BSA) | |
Sample pedestal material | Aluminum alloy and Quartz fiber | |
Power suppler | DC 12V 4A | |
Operating power | 48W | |
Standby power | 8W | |
Software | Android | |
Data Output | USB 2.0, in-built printer | |
OD600nm Measurement | ||
Light source | LED | |
Wavelength range | 600±8nm | |
Absorbance range | 0~4A | |
Fluorescence detection | ||
Type of tube | 0.5ml PCR Tube | — |
Excitation filters | wavelength 440nm (bandwidth 70nm) | — |
Emission filters | wavelength 545nm (bandwidth 30nm) | — |
Sensitivity | dsDNA: 0.5pg/μL | — |
Linear dynamic range | R2≥0.995 | — |
Repeatability | ≤1.5% | — |
Dimensions and Weight | ||
Dimension (W x D x H) | 318*220*205mm | |
Weight | 4.1kg |