Features
7-inch LCD touchscreen with intuitive user interface accomplishes detection without the need to connect to a computer
Only requires 0.5 - 2µl sample volume for accurate measurement.
Full spectral range of wavelength detection from 190nm to 800nm.
Simply power it on and start measuring, no need for lamp warm-up.
The Xenon flash lamp has long service life up to 10 years.
Automatic detection on lowering the pedestal arm.
OD600 function to detect concentration of bacteria and microorganisms.
For fluorescence detection, it can be used for accurate quantification of extremely low concentration nucleic acid with a lower limit of 0.5pg/µl(dsDNA).
The test result can be printed by a built-in printer or exported via USB for data analysis and storage.
Applications
The Micro Volume Spectrophotometer is used in the detection of micro-volume quantities of nucleic acids, proteins, chemical substances and liquids in laboratory, food industries, chemistry, microbiology, medicine research and development.
Features
7-inch LCD touchscreen with intuitive user interface accomplishes detection without the need to connect to a computer
Only requires 0.5 - 2µl sample volume for accurate measurement.
Full spectral range of wavelength detection from 190nm to 800nm.
Simply power it on and start measuring, no need for lamp warm-up.
The Xenon flash lamp has long service life up to 10 years.
Automatic detection on lowering the pedestal arm.
OD600 function to detect concentration of bacteria and microorganisms.
For fluorescence detection, it can be used for accurate quantification of extremely low concentration nucleic acid with a lower limit of 0.5pg/µl(dsDNA).
The test result can be printed by a built-in printer or exported via USB for data analysis and storage.
Applications
The Micro Volume Spectrophotometer is used in the detection of micro-volume quantities of nucleic acids, proteins, chemical substances and liquids in laboratory, food industries, chemistry, microbiology, medicine research and development.
Model | SPT-NanoF (built-in Fluorescence Detection) | SPT-Nano |
Wavelength range | 190-800nm | |
Minimum sample size | 0.5~2μL | |
Path length (auto-ranging) | 0.05mm (high concentration) | |
Light source | Xenon flash lamp | |
Detector type | 2048px, CMOS | |
Wavelength accuracy | 1nm | |
Spectral resolution | ≤3nm | |
Absorbance precision | 0.003Abs | |
Absorbance Accuracy | 1% (4.096A at 260nm) | |
Absorbance Range | 0.04~300A | |
Lower Limit of Detection | 2 ng/μL(dsDNA); 0.06 mg/mL (BSA) | |
Maximum Concentration | 15,000 ng/μL(dsDNA); 440 mg/mL (BSA) | |
Sample pedestal material | Aluminum alloy and Quartz fiber | |
Power supply | AC100V-240V, 50Hz/60Hz (power adapter) | |
Operating power | 48W | |
Standby power | 8W | |
Software | Android | |
Data Output | USB 2.0, built-in printer | |
OD600nm Measurement | ||
Sample Holder Type | Cuvette | |
Cuvette Dimensions | 12.5x12.5x45mm; Z-Height: 8.5mm | |
Light source | LED | |
Wavelength range | 600±8nm | |
Absorbance range | 0~4A | |
Fluorescence detection | ||
Sample Holder Type | 0.5mL PCR Tube (with PCR Tube Holder for Cuvette Slot) | — |
Excitation filters | wavelength 435-485nm | — |
Emission filters | wavelength 530-560nm | — |
Limit of detection | dsDNA: 0.5pg/μL | — |
Linear dynamic range | R2≥0.995 | — |
Repeatability | ≤1.5% | — |
Dimensions and Weight | ||
Dimension (W x D x H) | 318*220*205mm | |
Weight | 4.1kg |
Model | SPT-NanoF (built-in Fluorescence Detection) | SPT-Nano |
Wavelength range | 190-800nm | |
Minimum sample size | 0.5~2μL | |
Path length (auto-ranging) | 0.05mm (high concentration) | |
Light source | Xenon flash lamp | |
Detector type | 2048px, CMOS | |
Wavelength accuracy | 1nm | |
Spectral resolution | ≤3nm | |
Absorbance precision | 0.003Abs | |
Absorbance Accuracy | 1% (4.096A at 260nm) | |
Absorbance Range | 0.04~300A | |
Lower Limit of Detection | 2 ng/μL(dsDNA); 0.06 mg/mL (BSA) | |
Maximum Concentration | 15,000 ng/μL(dsDNA); 440 mg/mL (BSA) | |
Sample pedestal material | Aluminum alloy and Quartz fiber | |
Power supply | AC100V-240V, 50Hz/60Hz (power adapter) | |
Operating power | 48W | |
Standby power | 8W | |
Software | Android | |
Data Output | USB 2.0, built-in printer | |
OD600nm Measurement | ||
Sample Holder Type | Cuvette | |
Cuvette Dimensions | 12.5x12.5x45mm; Z-Height: 8.5mm | |
Light source | LED | |
Wavelength range | 600±8nm | |
Absorbance range | 0~4A | |
Fluorescence detection | ||
Sample Holder Type | 0.5mL PCR Tube (with PCR Tube Holder for Cuvette Slot) | — |
Excitation filters | wavelength 435-485nm | — |
Emission filters | wavelength 530-560nm | — |
Limit of detection | dsDNA: 0.5pg/μL | — |
Linear dynamic range | R2≥0.995 | — |
Repeatability | ≤1.5% | — |
Dimensions and Weight | ||
Dimension (W x D x H) | 318*220*205mm | |
Weight | 4.1kg |