Availability: | |
---|---|
FLR200HS
FEATURES
● Rapid Analysis: Achieve precise measurements in just 2.5 seconds per sample.
● High Sensitivity: Detect even minute quantities of biomolecules, with a lower limit of 10 pg/µL (original sample concentration) for dsDNA.
● Minimal Sample Volume: Obtain reliable results using sample volumes as small as 1-20 µL.
● Versatile Applications: Employ various dyes with pre-configured or custom standard curves to suit diverse experimental needs.
● Intuitive Interface: The 5.7-inch touchscreen provides a user-friendly experience, simplifying operation.
● Robust Data Storage: Store up to 10,000 programs and export data conveniently via USB drive.
FEATURES
● Rapid Analysis: Achieve precise measurements in just 2.5 seconds per sample.
● High Sensitivity: Detect even minute quantities of biomolecules, with a lower limit of 10 pg/µL (original sample concentration) for dsDNA.
● Minimal Sample Volume: Obtain reliable results using sample volumes as small as 1-20 µL.
● Versatile Applications: Employ various dyes with pre-configured or custom standard curves to suit diverse experimental needs.
● Intuitive Interface: The 5.7-inch touchscreen provides a user-friendly experience, simplifying operation.
● Robust Data Storage: Store up to 10,000 programs and export data conveniently via USB drive.
Model | FLR200HS |
Light sources | Blue LED (470nm peak) |
Red LED (635nm peak) | |
Excitation filters | Blue (450 - 490nm) |
Red (615 - 655nm) | |
Emission filters | Green (530 - 570nm) |
Red (680 - 720nm) | |
Detectors | Photodiodes: measuring range 310 - 1000nm |
Calibration type | 2 or 3-point standard |
Throughput | 1 |
Sample volume | 1-20μL |
Sample tube | 0.5mL PCR tube |
Measurement time | 2.5 seconds/sample |
Dynamic range (dsDNA) | 5 orders of magnitude |
Limit of detection | <10pg/µl |
Stability | <1.5% |
Repeatability | <1.5% |
Display | 5.7-inch touchscreen |
External ports | 2×USB-A |
Storage capacity | 4GB (10,000 programs) |
Power supply | AC100-240V, 50-60Hz |
Power input | 12V 3A |
Operating temperature | 5-40°C |
Operating humidity | 20-80% |
Weight | 0.7kg |
Size (W x D x H) | 135 × 245 × 50mm |
Model | FLR200HS |
Light sources | Blue LED (470nm peak) |
Red LED (635nm peak) | |
Excitation filters | Blue (450 - 490nm) |
Red (615 - 655nm) | |
Emission filters | Green (530 - 570nm) |
Red (680 - 720nm) | |
Detectors | Photodiodes: measuring range 310 - 1000nm |
Calibration type | 2 or 3-point standard |
Throughput | 1 |
Sample volume | 1-20μL |
Sample tube | 0.5mL PCR tube |
Measurement time | 2.5 seconds/sample |
Dynamic range (dsDNA) | 5 orders of magnitude |
Limit of detection | <10pg/µl |
Stability | <1.5% |
Repeatability | <1.5% |
Display | 5.7-inch touchscreen |
External ports | 2×USB-A |
Storage capacity | 4GB (10,000 programs) |
Power supply | AC100-240V, 50-60Hz |
Power input | 12V 3A |
Operating temperature | 5-40°C |
Operating humidity | 20-80% |
Weight | 0.7kg |
Size (W x D x H) | 135 × 245 × 50mm |
Fluorometer Reagents
Part Number | Description | Quantitation Range | Initial Sample Concertration | Number of Assays |
FLR-dsDNA | 1X dsDNA HS Assay Kit | 0.5-100ng | 0.025-100ng/μL | 100T |
FLR-ssDNA | 1X ssDNA HS Assay Kit | 0.5-200ng | 0.025-200ng/μL | 100T |
FLR-RNA | RNA HS Assay Kit | 0.5-200ng | 0.025-200ng/μL | 100T |
Fluorometer Reagents
Part Number | Description | Quantitation Range | Initial Sample Concertration | Number of Assays |
FLR-dsDNA | 1X dsDNA HS Assay Kit | 0.5-100ng | 0.025-100ng/μL | 100T |
FLR-ssDNA | 1X ssDNA HS Assay Kit | 0.5-200ng | 0.025-200ng/μL | 100T |
FLR-RNA | RNA HS Assay Kit | 0.5-200ng | 0.025-200ng/μL | 100T |